6850 West 47th Tr
Mission, KS 66203
(913) 268-6822

Local Reviews
for lone jack, mo

Rated 5.0 out of 5 stars based on 1 customer reviews

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for lone jack, mo

JJ H.

JJ H. Job Checkin

Capacitor replaced, ac is up and running. Thank you for choosing LBA services!


Andrew S.

Andrew S. Job Checkin

Arrived for ac check. Started at furnace and checked static pressure, it is failing. We have discussed this with you before. There is a 20 degree temp split. Wheel is clean. Running amps are good. I changed filter. At the condensing unit all pressures and charge look good. All electrical components are running within manufacturing specs. Coil is rinsed clean. System is running upon departure. Thanks for choosing LBA.


JJ H.

JJ H. Job Checkin

Went for an ac call today. Did a static pressure test it passed. Temperature split between supply and return duct passed. Blower motor amperage passed. Outdoor unit is very clean. Capacitor got replaced, due to the original one failing. Fan motor and compressor amperage passed. Refrigerant pressures met factory specifications. Thank you for choosing LBA services!


JJ H.

JJ H. Job Checkin

Replaced UV system. UV system works and furnace is up and heating. Thank you for choosing LBA services!


Robby M.

Robby M. Job Checkin

Completed furnace inspection for customer. All aspects of system tested within manufacturer specifications. No recommendations at this time. Customer stated that uv light wasn’t working properly, tested and it is malfunctioning. Called supplier to check warranty status, awaiting to hear back from them and then we will contact customer to return.


JJ H.

JJ H. Job Checkin

Bulb comes in Thursday or friday.


Tyler R.

Tyler R. Job Checkin

Upon arrival I began the furnace tune up. This is a Goodman systems that Ideal Temp installed back in March of 2022. I changed out the filter which is a 20x25x4 inch media filter. The old filter was extremely dirty. This is a reminder to change out your filter every 6 months with that type of filter. I also tried cleaning the return vent the best I could today. The blower wheel is very dirty and should be cleaned in the near future. The running amps on the inducer and blower motor were within manufacturer specifications. I took a temperature split on the system. It is rated for 15 to 45 degrees, 97 degrees(supply temp) - 67 degrees(return temp) = 30 degree temp rise is within specs. I did a test for any CO leaking from the heat exchanger but didn’t get any hits which is great! If you have any questions or concerns please feel free to call us! Your LBA Technician, Tyler Rickard P.S. No payment was due for todays visit, it was covered by your membership. I was to stress how important cha


JJ H.

JJ H. Job Checkin

Called customer


JJ H.

JJ H. Job Checkin

Went for a maintenance call today. Did a static pressure test, it passed. Tested the heat kit it passed. Blower motor amperage passed, but blower wheel is dirty. Ducts are also very dirty. Temperature split between the supply and return ducts passed. UV light is out, bulb needs replaced. Thank you for choosing LBA services!


Robby M.

Robby M. Job Checkin

Completed heating inspection for customer. Tested air handler and heat pump, heat pump functions normally and operates a 30-40 degree temp split, tested electric back up heat all coils energize and producing 50+degree air. All aspects test within manufacturer specs, no recommendations at this time.


JJ H.

JJ H. Job Checkin

Went in for a service call today. After hooking up the gauges I noticed that the suction side was low and that the discharge side was high. So I perceived that there was a restriction in the system. So I replaced the filter dryer inside the ac unit and cleaned the piston metering device. After refilling the system with refrigerant the system passed on superheat. The system was working properly when we finished. Thank you for choosing LBA Services!


JJ H.

JJ H. Job Checkin

Went for a service call today. Customer mentioned the house wasn’t cooling well. When checking pressures, I noticed the super heat was really high and the suction side was low. After doing a few tests, I figured out that the piston is clogged, going to replace filter dryer as well. Thank you for choosing LBA services!


Addison L.

Addison L. Job Checkin

8/19/2024 Today we returned to do install on an expansion tank and a small sprinkler line repair function restored to both. Vitals: -Water Quality: failed -Water heater: good After reviewing the entire house I went over everything with Clint to ensure they understood everything going on in the house and what could be done to address it. (Getting supervisor out?) Services done today: -install new expansion tank -small sprinkler line repair Thank you for choosing LBA Services Your technician, Addison


Addison L.

Addison L. Job Checkin

DATE 8/16/2024 Tested water quality and pressure. Looked at a leaking pvc line, and a water heater. Going back Monday to fix the sprinkler line and install new expansion tank Vitals: -Total Dissolved Solids: 223 -Water Pressure Static: 60 -Water Pressure Faucet Open: 53 -Water Temp Setting: -Water Temp Output: -Water Hardness: 5 -Water Quality: ph 8; chlorine 2 -Water Heater: -Water Lines: -Drain Lines: Wear and Tear: Failed expansion tank, leaking pvc line for irrigation. After reviewing the entire house I went over everything with Clint to ensure they understood everything going on in the house and what could be done to address it. (Getting supervisor out?) Solutions: Replace expansion tank. Remove & replace leaking pvc Services done today. Inspection and diagnosis Thank you for choosing LBA Services Your technician, Addison


Scott F.

Scott F. Job Checkin

Chuck’s main floor and upstairs unit both have much less airflow from the ductwork than is required for their cooling needs. Decreased the fan speeds in both units to temporarily relieve the excessive air pressure. Return visit scheduled for next Wednesday to review the findings and team up for solutions on the systems.